Please comply with all operation directions in this manual. Any misuse of a sterilizer or an autoclave, may cause bodily harm Alfa Medical Equipment Specialists Inc., will not be responsible for any misuse of the sterilizer or its parts. Pelton and Crane Delta (Model 8 and 10) Pelton and Crane Magna Clave: Pelton & Crane FL2: Prestige. Pelton & Crane OCM, OCR Service manual 1.6 MB Download Pelton & Crane Delta Q Service manual 1.6 MB Download Pelton & Crane Delta XL Service manual 5.9 MB Download PMT DSV70 Vertical Ciruit diagram 230 KB Download Prestige 2100 Service manual 670 KB Download Raypa AE 28,75,110,150 Service manual.
The Magna-Clave features a series of safety measures, like a Pelton & Crane-patented door lock that seals the entirety of the sterilizer’s rim, as well as clarity features like a series of indicator lights (“Power On,” “Heat On,” “Sterile,” and “Open Door”). Due to its large capacity, ease of use, and quick cycle speed (completes a flash cycle in 18 minutes from a warm start), it should come as no surprise that Pelton & Crane’s Magna-Clave is an industry-leading sterilizing unit
2Replies7 days ago | 7 days agoVoltage diagram? Voltage Leak I am having an issue with the door solenoid burning out. I replaced one and it was good for a few months then burnt out. Replaced another and it burnt out in a week along with some switches. I replaced all the switches, main relay and electrical contractor along with another door solenoid and it burnt out again and the door open light was slightly on even when the unit was in power off mode (but would light with full intensity when power was applied which made me think leak somewhere). I replaced the wall thermostat on the suggestion of a fellow tech and that fixed the weak light on the open door but I don't want to burn up another solenoid. SO before I throw another solenoid in this beast does anyone know what the voltage SHOULD be on the #2 wire in the different positions? # 2 wire that connects to the door solenoid has a leg coming from the pressure interlock switch and the open door light. RPI told me that the solenoid shouldn't be under constant voltage but I have 120VAC coming from that #2 wire to the body of the unit but I don't know if that's an acceptable test point. I don't have any voltage going from where the #2 wire connects to the solenoid to the pressure interlock switch. Reply |
-CPCC Dental Hygiene Program 3 years ago | 3 years agomagnaclave can I unstop a main valve....water fills super slow...or is this something that requires a tech...my filter is fine.Reply |
1Reply4 years ago | 4 years agoPelton Crane MagnaClave Does anyone have a proper wiring diagram for a Magnaclave showing wire numbers and connection schematic for the timer relay socket base. Mine blew out and the generic schematic is useless at best. Thanks in advance Reply |
Orientation | Floor Standing |
Featuring brightly-lit, easily-read touch panel graphics to enhance visibility and a variety of computer controls, the Delta XL10 is also one of our most aesthetically-pleasing autoclave units.
Other features include interior trays designed to prevent operator errors, a vented cover(which allows heat dissipation to prolong sterilizer life), and a metal cover that is removable from the front of the sterilizer to allow for easy maintenance and service. Among the most attractive user-access features are the automatic control settings, allowing users to simply select settings optimal for their sterilization needs and walk away, only needing to return to collect instruments.
2Replies6 years ago | 6 years agopelton crane operators manual Does anyone have the operators manual for pelton crane autoclave xl 10. Thanks Reply |
Orientation | Benchtop |